Diagnostic & Technical Explanation
Code P0131 (O2 Sensor Circuit Low Voltage Bank 1 Sensor 1) sets when the ECM sees an open circuit, a stuck/biased voltage, or no signal activity from an oxygen sensor's signal circuit. Causes are a contaminated or worn-out sensor element, an exhaust leak near the sensor bung skewing readings, or damaged sensor wiring.